Rising Bollards are of rising hydraulic or pneumatic cylinder systems that are used at the entrance gates of the buildings and facilities, shopping centers, embassies and consulates, bank offices, ports, refineries and prisons as well as the pedestrianization projects of the municipalities at the streets and boulevards in which the motor vehicle traffic is blocked.
They are easy to use, easy to install and, also safe thanks to their strong structure.
Rising Bollards can be integrated with a remote control, button, card access, automatic toll collection and license plate reading systems.
Rising Bollard Systems may be manufactured in any diameter and height according to the respective projects. It is possible to integrate a Security System, Photocell or Loop Detector into these system.
Unit operating voltage |
220V AC, Mono phase, 50/60 Hz |
Diameter |
220 mm |
Height |
740 mm- 900 mm |
Above-ground height |
540 mm – 700 mm |
Under-ground part |
830 mm – 990 mm |
Underground Cylinder Material |
Galvanized steel pipe |
Wall thickness (Top part) |
8-14 mm |
Surface coating |
2 mm chrome coated /304 stainless steel/ electrostatic paint |
Protection against corrosion |
Hot-dip galvanized and stainless steel coating |
Opening/closing time |
6-8 seconds |
Opening/closing capacity |
1000 / day |
Automation direction |
220V two-way solenoid valve |
Compressor |
50-100-200 lt |
Operation type |
Pneumatic system |
Pneumatic Cylinder Unit |
63×540 mm Pneumatic cylinder |
Pneumatic hose |
10-12 mm Pneumatic hose |
Pneumatic oil |
Pneumatic oil |
Operating temperature range |
-25 / 50 °C |
Field Cabinet |
Cabinet Size: 1100 x 1300 x 600 mm (height, width, depth) |
Control system |
Control with a standard remote control, and control with a button (optional) |
Control panel |
PLC based control, compatible with access systems (card access, license plate recognition fingerprint reader etc.) |
Emergency rising |
2 - 3 seconds (Optional) |
Manual opening/closing |
Manual pump |
Lighting |
Integrated LED lighting |
Warning equipment |
Traffic light (opsiyonel) |
Safety system security support |
Loop detector, Photocell |
Discharge pump |
Optional |
Operation in case of power outage |
Battery (optional) |